How to change personalities in Metadefender Optical Diodes

This article applies all deployments of Metadefender Optical Diode

Summary

The OD-101 and OD-102 personalities on MetaDefender Optical Diode appliances are interchangeable. You can switch between the two personalities on the same hardware as long as both Optical Diode appliances are running the exact same software version.

What Are OD-101 and OD-102 Personalities?

PersonalityDescriptionKey Characteristics
OD-101Common Criteria EAL4+ certified personalityEAL4+ certified mode High Availability disabled
OD-102High Availability (HA) personalityHA support enabled Not EAL4+ certified

Condition for Successful Interchange

The personalities can be freely interchanged and will work together correctly only when both diodes are on the same MetaDefender Optical Diode version (for example, both running version 1.13.1).

This ensures full compatibility of the personality file, license, and configuration between the two units.

When Would You Interchange Personalities?

  • Convert a unit from EAL4+ certified mode (OD-101) to HA-capable mode (OD-102) when redundancy becomes a requirement.
  • Switch from HA mode back to certified mode (OD-101) when Common Criteria EAL4+ compliance or audit needs change.
  • Repurpose spare appliances between different projects without hardware replacement.

How to Interchange the Personality

  1. Confirm that both MetaDefender Optical Diode appliances are updated to the identical software version.
  2. Log in to My OPSWAT Portal - One-stop Hub for Customers and Partners and download the desired personality file (OD-101 or OD-102) that matches the current software version.
  3. On the Optical Diode web interface, go to the License / Personality section.
  4. Upload the new personality file.
  5. Apply the change and reboot the appliance when prompted.
  6. Verify the active personality on the System Status or About page.

Important Notes & Limitations

  • After switching to OD-102, you can configure a High Availability pair.
  • After switching to OD-101, the appliance operates in EAL4+ certified mode and HA functionality is disabled.
  • Both units in an HA pair must use the same personality and the same software version.
  • Changing personalities does not require an RMA or hardware replacement.
  • Always back up the current configuration before performing a personality change.

This flexibility allows you to adapt the same physical MetaDefender Optical Diode appliances to evolving operational or compliance requirements without additional hardware purchases.

If Further Assistance is required, please proceed to log a support case or chatting with our support engineer.

VariableType to search · ESC to discard
GlossaryType to search · ESC to discard
InsertType to search · ESC to discard
No matches