Why is my OCMv7 missing the Deployment ID?
OCM relies on runtime components from the Microsoft Visual C++ 2013 Redistributable (x64). If these libraries are not present—or are an earlier build—the component that renders the Deployment ID cannot load, leaving the field empty.
- Required package: Visual C++ Redistributable Packages for Visual Studio 2013 (x64)
- Required version (minimum): 12.0.40664 (released April 2022)
Resolution
Download the redistributable
- Official Microsoft page: search for "Visual C++ Redistributable Packages for Visual Studio latest version".
- Direct download (64‑bit): https://aka.ms/highdpimfc2013x64enu
Install the package
- Run vcredist_x64.exe and follow the on‑screen prompts.
- A reboot is not usually required, but one is recommended if prompted.
Restart OPSWAT services
- Open Services.msc. Restart OPSWAT Central Manager Service (or restart the server during the optional reboot).
- Restart OPSWAT Central Manager Service by right-clicking the tray Icon and select Restart
Verify
- Log back in to OCM.
- Navigate to Dashboard › License and confirm that the Deployment ID now appears.
If Further Assistance is required, please proceed to log a support case or chatting with our support engineer.
Was this page helpful?