Notes for deployment of MD OT Security | Firewall Allow-listed Configurations
This document outlines the URLs and ports that must be allowed in the firewall to ensure proper functionality of the Network Sensor, Site Manager, and Enterprise Manager.
Allow-listed URLs
The following URLs are required for system operations and updates:
- https://my.opswat.com: Access to the OPSWAT business support portal.
 - https://activation.dl.opswat.com: License activation and validation.
 - https://mdots-cdn.opswat.com: Content delivery for updates and resources.
 
Allow-listed Ports
The following ports must be open for communication between components
Network Sensor
1443:
- Purpose: Using for communication from Site Manager to Network Sensor.
 - Only required when communication between Site Manager and Network Sensor is Bi-Directional. (ie: no need if communication between Site Manager and Network Sensor is Uni-Directional.)
 - Communication is secured by TLS 1.3.
 - Authentication is token-based.
 - Token lifecycle: 
- Version < 3.5.0: Token never expires until next established connection.
 - From version 3.5.0: Token will expire according to configuration.
 
 
443:
- Purpose: Using for user to perform initial configuration via web console.
 - Communication is secured by TLS 1.3.
 - Authentication: User account credentials.
 
Site Manager
3006:
- Purpose: For the communication between Site Manager with Network Sensor and Enterprise Manager.
- From Network Sensor to Site Manager (Uni-Directional and Bi-Directional)
 - From Enterprise Manager to Site Manager (Bi-Directional)
 
 
- Purpose: For the communication between Site Manager with Network Sensor and Enterprise Manager.
 5672:
- Purpose: Using for sending and receiving message queue service between Site Manager with Network Sensor and Enterprise Manager.
- Receiving and sending message from Network Sensor to Site Manager (Uni-Directional and Bi-Directional)
 - Receiving message from Enterprise Manager to Site Manager (Bi-Directional)
 
 
- Purpose: Using for sending and receiving message queue service between Site Manager with Network Sensor and Enterprise Manager.
 443:
- Purpose: Using for user to perform initial configuration via web console.
 - Communication is secured by TLS 1.3.
 - Authentication: User account credentials.
 
Enterprise Manager
443:
- Purpose: For user to work with MD OT Security Enterprise via web console.
 - Communication is secured by TLS 1.3.
 - Authentication: User account credentials.
 
3003:
- Purpose: 
- For user to work with MD OT Security Enterprise via web console.
 - For the communication between from Enterprise Manager to Site Manager. (Uni-Directional and Bi-Directional)
 
 
- Purpose: 
 5673:
- Purpose: Using for receiving message queue service from Site Manager (Uni-Directional and Bi-Directional)
 
Summary of open Ports on MD OT Security components for inbound connections
| Purpose/ Usage | Network Sensor | Site Manager | Enterprise Manager | 
|---|---|---|---|
| For users to use/ interact with the component via web console | 443 (main use-case: initial configurations) | 443 (main use-case: initial configurations) | 443 (User’s daily use of MD OT Security via Enterprise Management Console) | 
| For the lower component to communicate with the component | N/A (There is no MDOTS component under the sensor component) | 3006, 5672 (for Sensors to communicate with Site Manager) | 3003, 5673 (for Site Managers to communicate with Enterprise Manager) | 
| For the upper component to communicate with the component (only applicable if the communication between the two components is set to Bi-directional) | 1443 (For Site Manager to communicate with Sensor) | 3006, 5672 (for Enterprise Manager to communicate with Site Manager) | N/A (There is no MDOTS component above Enterprise Manager) | 
| For SSH Access | 22 | 22 | 22 | 
Summary of open Ports for outbound connections from MD OT Security components
| Purpose/ Usage | Connection from Network Sensor | Connection from Site Manager | Connection from Enterprise Manager | 
|---|---|---|---|
LDAP Authentication (For communicating with LDAP Server)  | 636 (secure) 389 (insecure)  | ||
Integration with NAC (For communicating with ClearPass Policy Manager Server)  | 443 | ||
| For Smart Asset Profiling | 80: HTTP for ABB profile 47808: UDP for BACnet/IP profile 80: HTTP for B&R Industrial Automation profile 18245: UDP for Emerson (GE-SRTP) profile 80: HTTP for Emerson (HTTP) profile 44818: TCP for EtherNet/IP profile 5562: TCP Mitsubishi profile 502: TCP for Modbus-TCP profile 34964: UDP for PROFINET IO (DCE/RPC) profile 102: TCP for S7COMM-PLUS profile - Extended 102: TCP for S7COMM profile 161: UDP for SNMP profile  | 
Notes
- Ensure that traffic is allowed for the listed URLs and ports.
 - Verify that no intermediate proxies or firewalls block these connections.
 - Contact the system administrator or OPSWAT support if additional configuration is required.
 